- Nume produs: SW7
- Nume alternative: Maşină de undă şoc focalizată, Maşină de terapie cu undă şoc electromagnetică, Echipament de fizioterapie cu undă şoc focalizată, Sistem de recuperare sportivă cu undă şoc
- Tehnologie: Undă şoc electromagnetică focalizată
- Energie condensator: 4,5–50 J
- Energie maximă: 50 J
- Adâncime de pătrundere: 1–70 mm, reglabilă
- Nivel de intensitate: 1–15 trepte
- Frequentia Activationis: 60‑120 Pulsus/Min (Circa 1‑2 Hz)
- Constitutio Frequentiae Tractationis: 30‑180 Pulsus/Min, 6 Gradus
- Modus Activationis: Continuus / Singularis
- Schermum: Schermum Tactile 10.1‑pollicare
- Caput Tractationis Normale: 1 x Manubrium SW Focus
- Caput Tractationis Optativum: 1 x Manubrium ED Focus
- Liquor Refrigerans: Aqua Purificata / Degassata aut Destillata secundum postulationes operationis
- Capacitas Recaricandi: 1 uF
- Potentia Nominalis: ≤550 VA
- Dimensiones Instrumenti: 39 Long. x 46.33 Lat. x 28 Alt. cm
DESCRIPTIO
Ut instrumentum clinicum rehabilitationis praecisum, systema SW7 undarum choccus electromagneticarum focalium technologiam energiae acusticae focalis provectam adhibet ad fluxus modernos physiotherapiae et recuperationis sportivae reformandos. Hoc dispositivum physiotherapeuticum undarum choccus regulabile est professionaliter calibratum ut energiam regibilem ad diversa strata textuum dirigat, quod SW7 idoneum reddit ad rehabilitationem normalizatam et conditionem physicam in institutionibus medicis et sportivis professionalibus.
Systema SW7 undarum choccus electromagneticarum focalium profunditatem focalem ultra-latifoliam regulabilem habet, quae a 1 mm usque ad 70 mm variat. Haec praecipua praerogativa machinam therapeuticiam undarum choccus praecisam ab limitibus penetrationis fixis liberat, et positionem accuratam pro reparatione tam textuum superficialium quam profundorum efficit. Cum energia condensatoris inter 4,5 J et 50 J, et cum 15 gradibus fortitudinis, hoc dispositivum physiotherapeuticum undarum choccus regulabile permittit therapistis omne tractamentum flexibiliter personalizare.
Constructus est cum duobus modis operativis; apparatus rehabilitativus sportivus multifunctionalis sustinet operationem continuam et singularem activationis. Frequentia activationis variat ab 60 ad 120 pulsus per minutum, dum sex gradus frequentiae therapeuticae amplectuntur a 30 ad 180 pulsus per minutum. Flexibilis configuratio frequentiae systematis SW7 undarum electromagneticarum focalium permittit adaptationem therapeuticam ad diversas corporis regiones et ad limina conforti utentis.
Apparatus therapeuticus undarum focalium praebet manubrium standardis focalis, quod sustinet tractationem totius corporis, inter quas cervix, humeri, dorsum, articuli et regiones contornandi corporis. Manubrium ED focalis optativum ulterius augent applicationes professionales, multumque augent versatilitatem huius apparatus rehabilitativi sportivi multifunctionalis.
Habens un schermu táctil intelligente de 10,1 pollicis, su sistema SW7 de ondas de choque electromagneticas focalizadas offrit indicatiónes in tempore réale de parámetros e suggerimentus de tractamentu standard. Registrat automáticamente datos intégrales de tractamentu comu intensidáde, frecuéntzia, énerghia e duráta, sustentandu un’administratzione professionale de casos. Cun un’acoplamentu professional de sacu de ácua e una strúctura de concentratzione de énerghia focalizada, custu dispositívu de fisioteràpia a ondas de choque regolàbile concentra l’énerghia eficace in zonas obiettìvu, garantìscende resultatos de fisioteràpia sècurus, accurados e efìcaces pro aplicatziones clìnicas e de riabilitatzione sportìva a longu términe.
Interfàtzia de tractamentu guidatu
- Selezione guidata de àreas corpòreas pro su manìghiu SW focalizadu standard.
- Parámetros de tractamentu de referéntzia visualizados in su schermu.
- Livellu de sacu de ácua regolàbile cun 5 impostatziones.
- Contu preimpostadu de colpis dae 500 a 5.000.
- Intensidáde de output regolàbile dae Livellu 1 a Livellu 15.
- Frecuéntzia de tractamentu regolàbile dae 30 a 180 pulsus/min in 6 livellos.
- Modus output automaticus continuus et modus output manualis singularis.
- Gestio informationum utentis et gestio recordum tractationum.
Applicationes
- Therapia physica: Designata pro programmatibus physiotherapeuticis professionalibus, quae communia loca tractationum musculoskeletal involvunt.
- Supportus recuperationis leSIONUM sportivARUM: Idonea pro programmatibus recuperationis sportivis, quae musculos, tendines, articulos et rehabilitationem post-exercitium spectant.
- Therapia rehabilitationis: Incorporari potest in programmatibus rehabilitationis professionalibus, quae profunditatem focalem et parametra energiae regulabilia exigunt.
- Supportus gestionis doloris: Technologia undarum aëris focalis adhiberi potest ut pars programmatum professionalium pro locis communibus incommodi musculoskeletal.
- Supportus contornationis corporis / cellulitis: Software optionem pro area tractationis contornationis corporis includit pro applicationibus aestheticis et salutis professionalibus.
- Supportus recuperationis articulorum et tendinum: Profunditas et intensitas regulabiles flexibilia parametra pro locis ut humerus, cubitus, genus, talus et pes praebent.
- Application ED optativus: Manubrium specialis focus ED optativum praebetur. Usus regulis localibus applicabilibus, protocollis professionalibus et inscriptionibus producti obsequi debet.
Specificationes
| Parametrum |
Specificatio |
| Nomen producti |
SW7 |
| Technologia |
Unda conmota electromagneticam focus |
| Voltage Operativum |
AC220V aut AC110V a fabrica electum, +10% / 50Hz |
| Energia condensatoris |
4,5–50 J |
| Energia maxima |
50 J |
| Profunditas Penetrationis |
profunditas focalis adiustabilis 1–70 mm |
| Gradus Fortitudinis |
1–15 gradus (4,5–50 J) |
| Frequentia activans |
60‑120 Pulsus/Min (Circa 1‑2 Hz) |
| Regulatio Frequentiae Tractationis |
30‑180 Pulsus/Min (6 Niveaux) |
| Modus Initii |
Continuus / Singularis |
| Scherma |
schermus Tactilis 10,1 Pollicum |
| Manubrium Normale |
1 x Manubrium SW Focus |
| Manubrium Optativum |
1 x Manubrium ED Focus |
| Potentia Nominalis |
≤550 VA |
| Liquidus Refrigerans |
Aqua Purificata / Degassata aut Destillata |
| Capacitas accusandi |
1 µF |
| Temperatura Interior |
10°C–30°C |
| Humiditas relativa |
≤80% |
| Pressura atmosphaerica |
760 Pa–1060 Pa (secundum specificatum) |
| Dimensiones Instrumenti |
39 L × 46,33 L × 28 A cm |
Configurationis
Configuratione Latin
- Hostis × 1
- Manubrium SW Focus × 1
- Rack Accessoriorum × 1
- Cupus Storagis Aquae x 1
- Cordus Electricus x 1
Configuratio optionalis
- Manus Focus ED x 1
- Trolleus x 1
Areae Tractationis
Secundum interfaciem regionis tractationis in manuali utentis, manus focus SW standardis praebet selectiones directas pro:
- Cervicem
- Humerus
- Dorsum
- Regio Nates / Coxa
- Angulus
- Carpi
- Manus
- Genu
- Crus
- Talus
- Pes
- Regio Corporis Contornantis / Adipis
Virtutes Competitivae
- profunditas Focus Regulabilis 1–70 mm: Amplia regulatio profunditatis subvenit planificationi tractationis pro regionibus superficialibus et profundioribus.
- Energia Usque ad 50 J: Energia condensatoris regulabilis est ab 4,5 usque ad 50 J per 15 gradus fortitudinis.
- Deliveria Energiae Concentratae: Designum undarum choc concentrat energiam acousticam circa regionem focus electam pro applicatione professionali targetata.
- Interfacsia Tractationis Directa: Selectio regionis corporis et parametri referentiales in schermo adiuvant ut fluxus operis professionalis simplificetur.
- Modi Continui + Singuli: Usor potest eligere emissionem automaticam continuam vel emissionem manualem singulam secundum requisita applicationis.
- Adiustamentum Frequentiae Sex Graduum: Frequenta tractationis adiustari possunt ab 30 ad 180 pulsus per minutum in sex gradibus.
- Registra Tractationum Usoris: Systema potest conservare diem tractationis, regionem, intensitatem, frequentiam, numerum impulsuum, energiam et duratio tractationis.
- Coupling Sacculi Aquosi Adiustabilis: Quinque niveles sacculi aquosi adiutant ad controllandum coupling et positionem focus durante operatione.
- Manubria Standard + Optativa: Manubrium SW focus standardis suffragat multas regiones corporis, dum manubrium ED optativum systematis configurationem augent.
- schermum Tactile 10.1-pollicare: Grandis interfacsia tactilis commodam electionem tractationis, adiustationem parametrorum et constitutiones systematis praebet.
PRINCIPALES FUNCTIONES
- Supportat applicationes physiotherapeuticas professionales.
- Supports recuperatio vulnerum sportivorum et programmatum rehabilitationis post-exercitium.
- Supports programmatum therapiae rehabilitationis professionalium.
- Supports applicationes benessi ad contornationem corporis et cellulitem spectantes.
- Configuratio manubrii ED specialis optabilis est pro usibus professionalibus applicabilibus.
- Praebet interfaciem tractationis directricem cum positionibus referentiarum arearum tractationis.
- Energia concentrata et profunditas focalis regolabilis ita sunt designatae ut tractationem in regione praeselecta concentrent.
Cur SW7 eligere debes?
SW7 combinat technologiam undarum crepitantis electromagneticarum focalium, profunditatem focalem regolabilem 1–70 mm, energiam usque ad 50 J, 15 gradus fortitudinis, softwarem directricem arearum tractationis et modos flexibiles continuos/singulos. Functiones eius professionalis controlus parametrorum et registri tractationum eum idoneum faciunt ad clinicas physiotherapiae, centra recuperationis sportivorum, instituta rehabilitationis et applicationes benessi professionalis selectas.
Nota Importans de Conformitate Situs Interretialis
Manuale utente fornito afferma che il prodotto non è classificato come dispositivo medico e non deve essere presentato per il trattamento di malattie. Le affermazioni sul sito web devono quindi concentrarsi su fisioterapia, riabilitazione, recupero e supporto al benessere, ed essere adattate ai requisiti normativi del mercato di destinazione.
TAG
SW7, Machina pro Ondas de Choque Concentradas, Ondas de Choque Electromagnéticas, Terapia con Ondas de Choque Concentradas, Máquina de Fisioterapia con Ondas de Choque, Corporalis Therapy Equipment , Equipamento para Recuperação Desportiva, Equipamento para Reabilitação, Ondas de Choque com Foco Ajustável, Máquina de Ondas de Choque de 50 J, Profundidade de Foco de 70 mm, Equipamento para Recuperação Musculoesquelética, Equipamento para Recuperação Articular, Equipamento para Recuperação Tendinosa, Máquina de Ondas de Choque para Celulite, Equipamento para Contorno Corporal, Máquina de Ondas Acústicas Concentradas, Sistema de Tratamento com Ondas de Choque