Salvete in officiali pagina interretiali GOMECY! Disputemus et cooperemur!

gomecy-shockwave-448khz-tecar-cet-ret-body-care-physiotherapy-system-2-in-1, gomecy-shockwave-448khz-tecar-cet-ret-body-care-physiotherapy-system-2-in-1, /radial-shockwave-therapy
gomecy-shockwave-448khz-tecar-cet-ret-body-care-physiotherapy-system-2-in-1, gomecy-shockwave-448khz-tecar-cet-ret-body-care-physiotherapy-system-2-in-1, /radial-shockwave-therapy
Inquisitio
gomecy-shockwave-448khz-tecar-cet-ret-body-care-physiotherapy-system-2-in-1, gomecy-shockwave-448khz-tecar-cet-ret-body-care-physiotherapy-system-2-in-1, /radial-shockwave-therapy
gomecy-shockwave-448khz-tecar-cet-ret-body-care-physiotherapy-system-2-in-1, gomecy-shockwave-448khz-tecar-cet-ret-body-care-physiotherapy-system-2-in-1, 
Inquisitio

GOMECY Shockwave 448 kHz Tecar CET RET Body Care Physiotherapy System 2 IN 1

Hoc unitas 2-in-1 integrat undam choc et radio-frequentiam CET-RET 448K in duobus modis, multos apices, et parametres regolabiles pro physiotherapia, rehabilitatione sportiva et cura corporis-cutis aesthetica.

 

Locus originis Beijing, China
Nomen Marca GOMECY
Numerus Exemplaris GMS-SW139
Certificatio CE, ISO13485

 

Pete Citationem
  • Conspectus

Conspectus

Termini Negotiationis Producti

Minimum quantitas ordinis 1
Singula Packaging Magnitudo pacheti: 45 cm × 49 cm × 55 cm
Pondus brutum: 27 kg
Tempus Traditionis 12–18 dies laborales per aerem, 25–35 dies laborales per mare
Condiciones solutionis T/T bank transfer, Western Union, Alipay
Capacitas Supplicandi 500 units/month

Brevis Detalia

  • Typus producti: Systema curae corporis et physiotherapia shockwave + 448KHZ
  • Technologiae: Shockwave, CET 448K (modus capacitivus) et RET 448KHZ (modus resistivus)
  • Usus principales descripti in manuali: subsidium contra dolorem et pro mobilitate, cura cellulitis/corporis, firmatio et renovatio cutis, subsidium circulationis, drenatio lymphatica et conformatio corporis
  • Monitor: schermum tactilis 12,1‑pollicare
  • Frequentia shockwave: 1–16 Hz
  • Frequentia CET/RET: 448KHZ
  • CET potensia: ≤100 W; RET potensia: ≤180 W
  • Potensia undae impulsivae: ≤180 W
  • Specificatio cito: Energia undae impulsivae 5–200 MJ; frequentia undae impulsivae 1–18 Hz; frequentia RF 300–450 kHz; septem capita undae impulsivae; duo manubria Tecar cum sex capitibus; AC 110 V–220 V, 50 Hz/60 Hz
  • Applicatio principalis: alleviatio doloris, therapia physica, rehabilitatio, recuperatio a laesionibus sportivis, recuperatio musculorum, cura corporis et firmatio cutis, adiuvata a functionibus Tecar/undae impulsivae

DESCRIPTIO

Sistemo GMS‑SW139 por korpa zorgo per ondoj de ŝoko estas integrita kombinita terapia aparato por ondoj de ŝoko kaj radiofrekvenco, kiu kunigas intervenon per ondoj de ŝoko kun funkcioj de radiofrekvenco CET 448K kaj RET en unu kompakta aparato. Rompante la limojn de ekipaĵoj kun unu sola funkcio, GMS‑SW139 liveras fizikan intervenon de du kategorioj, ebligante al klinikoj kaj beleco-salonoj plenumi kaj fizioterapion por rehavigo kaj kosmetikan korpan zorgon sen bezono de pluraj apartaj aparatoj. Ĉi tiu multumoda ekipaĵo por korpa rehavigo optimaligas la investon en aparatojn kaj plirichigas la gamon de disponeblaj traktaj programoj por profesiaj servaj lokoj.

Modulus undae choccantis systematis GMS‑SW139 pro cura corporis (448 kHz) operat per generationem stimulorum pressionis rapide variantium ad zonas textus designatas. Haec stimulatio mechanica auxiliatur opere physiotherapeutico cotidiano, levat molestias corporales, meliorat mobilitatem corporis, et etiam ad ritus cellulitidis et curae corporis applicari potest. Ab interventionibus basatis in calore diversum est: energia mechanica undae choccantis agit in structuras textuum ex perspectiva physica, effectus auxiliares unicos creans pro conditionamento textuum mollis.

Pars 448K frequenciae radioelectricae huius dispositivi combinati therapiae undarum choc et frequenciae radioelectricae duas habet modos operationis distinctos. Modus CET utitur designo electrodii capacitivi isolati ad producendum calorem superficialem regulatum, ita ut comoditas epidermidis per totam operationem bene servetur. Per contra, modus RET transmittit energiam altius frequenticam in profunda tessutum humanorum, ut pronuntiatae responsum thermicum profundum generentur. Hi duo modi diversimode agunt in stratis tessutum, operatoribus optiones flexibiles praebentes pro calefactione superficiali et conditionamento thermico stratorum profundorum.

Set completi di accessori sono configurati per la macchina di bellezza e fisioterapia CET RET. Gli accessori hardware includono la maniglia CET, la maniglia RET, la piastra di ritorno elettrodica, la maniglia ad onde d’urto e le punte di trattamento sostituibili. Gli operatori possono sostituire gli accessori corrispondenti in base ai progetti selezionati. Un touchscreen da 12,1 pollici funge da pannello di controllo centrale, dove tutti i parametri di trattamento possono essere modificati in conformità alle regioni corporee target e ai protocolli clinici preimpostati.

GMS‑SW139 multi‑modus corpus rehabilitatio apparatus late et practico usus casus sustinet. Projecta disponibilia includunt cutem firmare et renovare, circulationem localem promovere, drenagium lymphaticum, formam corporis modulare, cellulitidem meliorare, musculorum et articulorum relaxationem, simul cum physiotherapia standardi per undas percussivas. Sive utentes ad rehabilitationem physicam vel ad cosmeticam corporis conditionem tendunt, systema curae corporis per undas percussivas 448KHZ solutiones multi‑modus adaptabiles praebet, quae diversificatas necessitates practicas institutionum physiotherapeuticarum et centrorum pulchritudinis praecellentium complent.

Principium Operativum

Shockwave: Manualis definit shockwave ut undam quae per brevissimum tempus rapida pressione crescit, deinde graduatim pressione decrescit et parva fase negativa pressionis sequitur. Shockwaves ad regionem destinatam diriguntur. Manualis affirmat influentiam mechanicam eorum vascularizationem iuvare, deposita calcificata afficere, tensionem textus minuere et effectum analgesicum praebere.

448KHZ CET (Modus Capacitivus): CET utitur electrodum capacitivum isolatum. Manualis describit processum quo energia radio-frequens calorem in strata cutis profundiora conducit, dum epidermis confortabilis manet. Particulae et ionia cumulata moventur aut vibrare sub campo altae frequentiae, energiam thermicam producentes. Manualis hanc calefactionem regulatam cum contractione collageni et stimulatione novi collageni coniungit, quae turgentiam cutis, emendationem rugularum, elasticitatem et aspectum cutis iuvant.

448KHZ RET (Modus resistif): RET projektit energiam alti-frequentiam in tessuras corporis ad generandum calorem profundum. Cum currente alternante mutat directionem, moleculae tessurarum vibrat et creant motum rotationalem, torsionalem et frictionalem, producens effectus thermicos. Manuale associat RET cum calefactione profunda, circulatione, drenatione lymphatica, sustentatione tessurarum et applicationibus curae corporis.

Applicationes

  • Physiotherapia ondularum choccantis et subsidium pro tractatione doloris
  • Restitutio mobilitalis et applicationes physiotherapiae sportivae/orthopaedicae
  • Reductio cellulitidis, firmatio et levigatio cutis
  • Elevatio, contractio et rejuvenatio cutis
  • Protocolli pro rugis et cura acne
  • Subsidium pro circulatione sanguinea et drenatione lymphatica
  • Formatio corporis et protocolli pro gestionem ponderis/cura corporis
  • Dolor musculorum et relaxatio artuum rigidorum
  • Protocolli pro cura corporis post partum pro laxitate
  • Protocollum facialium et corporalium, inter quae duplex mentum, brachia, collum/décolleté, abdomen, nates, sacculi laterales, cellulitis inferioris corporis, manus et pedes

Specificationes

Parametrum Specificatio
Nomen producti machina Therapeutica Tecar Shockwave 2‑in‑1
Modellum SW139
Scherma schermus tactilis 12,1‑pollicis
Summa potentia ≤600 W
Potentia CET ≤100 W
Potentia RET ≤180 W
Frequentia CET/RET 448K
Shockwave Power ≤180 W
Energia Undarum Impactualium Dependentia ab frequentia; manuale describit 60–185 mJ ad 1–12 Hz, 60–120 mJ ad 13–14 Hz, et 60–90 mJ ad 15–16 Hz
Spatium Maximum 50–200 mJ
Potentia Input AC 110V–220V, 50Hz/60Hz
Applicatio Physiotherapia, doloris alleviatio, rehabilitatio, recuperatio a laesionibus sportivis, cura corporis
Technologia Tecar CET/RET + Shockwave
Nota GOMECY
MOQ 1 unit

Commodum Competitivum

  • plataforma functionalis 2-in-1 quae combinat technologias Shockwave + 448K CET + 448K RET, et quae utramque protocolum physiotherapeuticum et curam corporis/cutis in uno systemate supportat
  • operatio per schermum tactilis 12.1-pollicem
  • Parametri frequentialis et energiae shockwave regulabiles
  • Multiplae apices manubrii shockwave et apices tractationis CET/RET pro diversis regionibus tractandis
  • CET et RET offrent des modes de traitement capacitif et résistif 448K complémentaires
  • Zones prédéfinies de traitement par ondes de choc et interface de paramètres décrites dans le manuel
  • Large éventail de protocoles de traitement facial et corporel répertoriés dans le guide d’utilisation

TAG

machine de thérapie par ondes de choc, système de soins corporels 448K, machine CET RET, équipement de kinésithérapie, machine de modelage corporel, système de traitement de la cellulite, équipement de raffermissement cutané, thérapie antalgique, équipement de récupération sportive, soins corporels par radiofréquence

Producta insignes

Accipe Aestimationem Gratuitam

Legatus noster te mox contactabit.
Epistula electronica
Mobilis aut WhatsApp
Nomen
Nomen societatis
Nuntius
0/1000